996 Turbo diagnostic manual — Turbo applicability only / PAGE 1047
96-44Fault code 39 · Signal converter faulty
Read extracted page text
OCR can contain errors. Check the original page image for exact wording, warnings and specifications.
911 Turbo (996) Alarm system I 48 96
96-44Fault code 39
Signal converter faulty
Diagnostic conditions
• Terminal 86 S or terminal 15 on
Possible cause of fault
♦Short circuit to voltage/ground or open circuit in the wiring
between the alarm system control module and the signal con-
verter
Affected terminals
Plug A, terminals 3 and 4
Diagnosis/troubleshooting
Work instruction Display OK If not OK
1 Check power supply of ♦Switch off ignition > 11 V Repair wiring har-
the signal converter ⇒ Step 2 ness ♦Pull plug off the signal converter
♦Switch on terminal 86 S
♦Measure voltage between plug
on the signal converter pin 5
and ground
♦Measure voltage between the
plug on the signal converter pin
5 and pin 4
2 Check wiring from signal ♦Switch off ignition ∞ Ω Repair wiring har-
converter to alarm sys- ⇒ Step 3 ness ♦Pull plug A off the alarm system
tem control module for → End control module
short circuit to ground
♦Measure resistance between
plug on alarm system pin 3 and
ground
♦Measure resistance between
plug on alarm system pin 4 and
ground
3 Check wiring from signal ♦Switch on ignition 0 V Repair wiring har-
converter to alarm sys- ⇒ Step 4 ness ♦Measure voltage between plug A
tem control module for → End on control module pin 3 and
short circuit to B+ ground
♦Measure voltage between plug A
on control module pin 4 and
ground
9601 Fault code 39 96-44 page 1
Printed in Germany – 2, 2001 39xxxi48
This is a source reference. Confirm exact model applicability in the original material.