996 Turbo diagnostic manual — Turbo applicability only / PAGE 1084
Work instruction Display OK If not OK · 5 Check micro switches of
Read extracted page text
OCR can contain errors. Check the original page image for exact wording, warnings and specifications.
911 Turbo (996) Alarm system I 48 96
Work instruction Display OK If not OK
5 Check micro switches of ♦Push plugs A and B back onto Driver’s side not ⇒ Step 11
the two door locks (pos- the alarm system control mod- locked
sible detection of faulty ule Passenger’s side
driver’s/passenger’s not locked ♦Reconnect plugs to both door
door lock) Driver’s side not locks
secured (not appli-
♦Close doors cable to USA vehi-
♦Vehicle not secured and not cles)
locked Passenger’s side
not secured (not ♦Select "Driver’s side locked",
applicable to USA "Passenger’s side locked"
vehicles) "Driver’s side secured" and
⇒ Step 12 "Passenger’s side secured" in
menu item "Input signals".
6 Check central locking ♦Remove central locking switch Central locking
switch and pull plug off the switch switch actuated in
"open" direction ♦Measure resistance between
< 5 Ω pins 4 and 1 on the central
Central locking locking switch
switch not actuated
in "close" direction
∞ Ω
⇒ Step 6
7 Check central locking ♦Measure resistance between Central locking
switch pins 4 and 2 on the central switch actuated in
locking switch "open" direction
< 5 Ω
Central locking
switch not actuated
in "open" direction
∞ Ω
⇒ Step 7
8 Check the wire from the ♦Pull plug off central locking ∞ Ω
central locking switch to switch ⇒ Step 8
the control module for ♦Pull plug A off the alarm sys-
short circuit to ground tem control module
♦Measure resistance between
plug A on control module pin
29 and ground
9 Check the wire from the ♦Measure resistance between
central locking switch to plug A on control module pin
the control module for 29 and plug on switch for cen-
open circuit tral locking pin 1
10 Check the wire from the ♦Measure resistance between approx. 180 Ω at
central locking switch to pins 1 and 2 of plug for central 20 °C
the control module for locking switch ⇒ Step 10
open circuit
9601 Fault code 61 96-63 page 3
Printed in Germany – 4, 2001 61xxxi48
This is a source reference. Confirm exact model applicability in the original material.