Porsche DME 7.8 — OBD II Diagnosis Manual / PAGE 40
DME 7.8 DME 7.80 · This may be important in the case of output to a scan tool, as there
Read extracted page text
OCR can contain errors. Check the original page image for exact wording, warnings and specifications.
DME 7.8 DME 7.80
This may be important in the case of output to a scan tool, as there
may be only one freeze frame that can be displayed, although sev-
eral faults are stored (misfires or fuel supply faults override the
freeze frames of other faults).
Freeze frames can, for example, be examined in the "extended fault
memory" of the 9588 Porsche System Tester ll.
The control module must be able to output the following freeze
frame data to a standard diagnostic unit (scan tool):
♦Fault codes causing this freeze frame to be stored
♦Engine load
♦Engine speed
♦Coolant temperature
♦Oxygen control status (open or closed loop)
♦Mixture adaptation values
♦Fuel pressure (if available - not the case for DME 7.8)
♦Intake pipe pressure (if available - in the case of DME 7.8 for
turbo vehicles only)
♦Vehicle speed
In the case of DME 7.8, a freeze frame is stored for each initial
occurrence of a fault that contains all the actual values referred to
above with the exception of fuel pressure. See also the next sec-
tion.
Further environmental conditions
In addition with DME 7.8, for every occurrence of a fault, three fur-
ther operating conditions (actual values at time of fault occurrence)
as well as operating hours and total mileage since model year 2002
are also stored. There is a memory entry for the first occurrence of
the fault (remains stored) and a further entry for each last occur-
rence of the fault (updated for each new occurrence). This data can
provide reference points to the cause of the fault in difficult diag-
noses and can only be viewed in the "extended fault memory" of the
9588 Porsche System Tester II. The list of possible environmental
conditions partly covers more than one freeze frame so that impor-
tant environmental conditions can also be stored after the first fault
occurrence.
Fault persistence (confirmation of a suspected fault)
When a fault occurs for the first time during a diagnostic routine, it
is stored as a suspected fault. At the same time a fault persistence
counter is started with a certain value (e.g. 2). In the course of fur-
0-PEIN page 6 2470 INTRODUCTION
PEIN2DME78 Printed in Germany – 14, 2003
This is a source reference. Confirm exact model applicability in the original material.
