Porsche DME 7.8 — OBD II Diagnosis Manual / PAGE 63
DME 7.8 DME 7.8 0 · The new programming code must match the DME programm
Read extracted page text
OCR can contain errors. Check the original page image for exact wording, warnings and specifications.
DME 7.8 DME 7.8 0
Note!
The new programming code must match the DME programming
code from the IPAS, otherwise the control module can no longer be
programmed later.
♦Enter and confirm 'New immobilizer code'.
Note!
The new immobilizer code must match the immobilizer code from
the IPAS, otherwise the control module can no longer be pro-
grammed later.
♦Select data record.
Note!
♦If the data record OBD II was selected in the old control module,
the tester automatically preselects "Data record OBDII".
♦The selection must then simply be confirmed. Programming
commences after this confirmation.
♦When programming is complete, switch off the ignition.
♦Switch on the ignition.
♦Switch off the tester.
Note!
In Tiptronic vehicles, the fault memory of the Tiptronic must be
erased following the programming of a DME control module, as the
fault "CAN timeout" is entered in the memory during programming.
3. Program map/data
The data record can be changed, e.g. from RoW to OBD II, with this
menu item. Only the DME programming code is required.
4. Program immobilizer code
The immobilizer code is transferred to a new DME control module
with this menu item.
Data Output with the Porsche System Tester 2 0-2a page 13
Printed in Germany – 4, 2002 pst_dm78
This is a source reference. Confirm exact model applicability in the original material.