Porsche DME 7.8 — OBD II Diagnosis Manual / PAGE 74
DME 7.8 DME 7.80 · Bit 0 Bank 1, sensor 1 (ahead of TWC, cylinders 1 - 3)
Read extracted page text
OCR can contain errors. Check the original page image for exact wording, warnings and specifications.
DME 7.8 DME 7.80
Bit 0 Bank 1, sensor 1 (ahead of TWC, cylinders 1 - 3)
Bit 1 Bank 1, sensor 2 (after TWC, cylinders 1 - 3)
Bit 2 Bank 1, sensor 3 not installed
Bit 3 Bank 1, sensor 4 not installed
Bit 4 Bank 2, sensor 1 (ahead of TWC, cylinders 4 - 6)
Bit 5 Bank 2, sensor 2 (after TWC, cylinders 4 - 6)
Bit 6 Bank 2, sensor 3 not installed
Bit 7 Bank 2, sensor 4 not installed
0 – Sensor not available.
1 – Sensor available.
$15 Oxygen sensor signal, bank 1, sensor 2
Output of oxygen sensor voltage and associated oxygen sensor.
Display of sensor voltage between 0 V and 1.275 V and of the oxy-
gen sensor in percent.
In the case of decimal output, conversion factor = 0.005
Decimal value displayed multiplied by 0.005 gives the voltage of
oxygen sensor.
Note!
Since the sensor behind the catalytic converter is not included in the
closed-loop control, no value for the oxygen sensor is displayed.
$19 Oxygen sensor signal, bank 2, sensor 2
Output of oxygen sensor voltage and associated oxygen sensor.
Display of sensor voltage between 0 V and 1.275 V and of the oxy-
gen sensor in percent.
In the case of decimal output, conversion factor = 0.005
Decimal value displayed multiplied by 0.005 gives the voltage of
oxygen sensor.
Note!
Since the sensor behind the catalytic converter is not included in the
closed-loop control, no value for the oxygen sensor is displayed.
0-3 page 10 Data output with a scan tool