Porsche DME 7.8 — OBD II Diagnosis Manual / PAGE 92

DME 7.8 DME 7.80 · 0 0 0 0 0 0 1 0

Add to repair workspace
Open repair workspace
Open full manual Original source
Original manual page 92
Read extracted page text

OCR can contain errors. Check the original page image for exact wording, warnings and specifications.

DME 7.8 DME 7.80 0 0 0 0 0 0 1 0 7 6 5 4 3 2 1 0 Bit Bit 0 Open-loop control; the conditions for oxygen sensing are not yet fulfilled. Bit 1 Closed-loop control; the signal from the oxygen sen- sor is used to control injection. Bit 2 Open-loop control through conditions such as full load, etc. Bit 3 Open-loop control due to fault in system. Bit 4 Closed-loop control, but faults from at least one oxy- gen sensor. Bits 5 to 7 not used. Note! Only one bit at a time can be set to 1 to indicate the status. $04 Calculated load value Output of calculated load as a percentage of the maximum load. Display between 0% and 100%. In the case of decimal output, conversion factor = 0.3921568 The decimal value displayed multiplied by 0.3921568 gives the load as a percentage. $05 Engine coolant temperature Output of the momentary engine coolant temperature. Display between -40 °C and 215 °C. In the case of decimal output, conversion factor = 1 Offset = -40 °C Decimal value displayed multiplied by 1 minus 40 °C gives the cool- ant temperature. $06 HO2S integrator, bank 1 Output of the control value FR of the oxygen sensor closed-loop con- trol, bank 1. 0-3.1 page 6 Data output with a scan tool - 911 Carrera (996) dsc_FL78 Printed in Germany – 8, 2002