Porsche DME 7.8 — OBD II Diagnosis Manual / PAGE 195

DME 7.8 DME 7.80 · Work instruction Display OK

Add to repair workspace
Open repair workspace
Open full manual Original source
Original manual page 195
Read extracted page text

OCR can contain errors. Check the original page image for exact wording, warnings and specifications.

DME 7.8 DME 7.80 Work instruction Display OK If not OK 1 Check that oxygen sen- ♦Check if the oxygen sensors ⇒ Step 2 Install the oxygen sors are allocated cor- were exchanged due to incor- sensors correctly, rectly rect installation of or tampering eliminate cause of with the wiring harness damage if neces- sary → End 2 Check oxygen sensor wir- ♦Disconnect oxygen sensor plug < 2 Ω Continue with find- ing harness ahead of cat- connection ahead of catalytic ⇒ Step 4 ing damage alytic converter, bank 1 converter, bank 1 ⇒ Step 3 → End ♦Visual inspection ♦Remove control module connec- tor B ♦Visual inspection Check following wiring for continuity ♦Oxygen sensor connector ahead of catalytic converter pin 1 and DME control module connector B pin 15 ♦Oxygen sensor connector ahead of catalytic converter pin 5 and DME control module connector B pin 9 ♦Oxygen sensor connector ahead of catalytic converter pin 2 and DME control module connector B pin 2 ♦Oxygen sensor connector ahead of catalytic converter pin 6 and DME control module connector B pin 5 0-P0040 page 2 2470 P0040 p0040 Printed in Germany – 13, 2003