DME 7.8 DME 7.8 0 · 0-8.17P0045

Add to repair workspace
Open repair workspace
Open full manual Original source
Original manual page 197
Read extracted page text

OCR can contain errors. Check the original page image for exact wording, warnings and specifications.

DME 7.8 DME 7.8 0 0-8.17P0045 Charge Pressure Control Valve Output Stage - Open Circuit Diagnosis conditions • Ignition on Possible fault cause ♦Charge pressure control valve (coil) open circuit ♦Open circuit in wiring Affected terminals III/4 Diagnosis/Troubleshooting Work instruction Display OK If not OK 1 Check charge pressure ♦Measure resistance at the 20 - 26 Ω at 20 °C. control valve. charge pressure control valve. 2 Check wiring harness for ♦Connect special tool to wiring 0 - 5 Ω Repair wiring har- open circuit. harness (DME control module ness plug). → End. ♦Remove connector of charge pressure control valve. ♦Measure resistance between special tool 9637 pin III/4 and charge pressure control valve plug pin 2. 2193 P0045 0-8.17 page 1 Printed in Germany – 6, 2002 p0045

This is a source reference. Confirm exact model applicability in the original material.