Porsche DME 7.8 — OBD II Diagnosis Manual / PAGE 230

DME 7.8 DME 7.8 0 · 0-14P0113

Add to repair workspace
Open repair workspace
Open full manual Original source
Original manual page 230
Read extracted page text

OCR can contain errors. Check the original page image for exact wording, warnings and specifications.

DME 7.8 DME 7.8 0 0-14P0113 124 Intake air temperature sensor - above limit Diagnosis conditions • Idle speed • Time elapsed after engine start-up greater than 2 seconds Possible fault cause ♦Short circuit to ground Note! A substitute value (approx. 60 °C) is used in the event of a fault. Affected terminals Terminal III/34 Diagnosis/troubleshooting Work instruction Display OK If not OK 1 Check wiring from DME ♦Remove plug of temperature ∞ Ω Repair wiring har- control module to temper- sensor → End ness ature sensor for short to → End ♦Connect special tool 9637 to ground wiring harness (DME control module connector). ♦Measure resistance between special tool 9637 Pin III/34 and ground 2488 P0113 0-14 page 1 Printed in Germany, 2000 p0113