Porsche DME 7.8 — OBD II Diagnosis Manual / PAGE 236

DME 7.8 DME 7.8 0 · 0-15.1P0116

Add to repair workspace
Open repair workspace
Open full manual Original source
Original manual page 236
Read extracted page text

OCR can contain errors. Check the original page image for exact wording, warnings and specifications.

DME 7.8 DME 7.8 0 0-15.1P0116 Engine Temperature – Signal Implausible Diagnosis conditions • A temperature model is formed. If the measured temperature deviates too much from the calculated temperature, a fault is detected. Note! A thermostat which is constantly open can cause the fault P0115. Possible fault cause ♦Thermostat (permanently open) ♦Open coolant shutoff valve (only Tiptronic vehicles) ♦Wiring ♦Temperature sensor faulty ♦DME control module faulty Affected terminals Terminal III/22 and III/17 Resistance values 0 °C 5.0 -7.0 kΩ 20 °C 2.0 - 3.0 kΩ 60 °C 0.4 -0.8 kΩ Diagnosis/Troubleshooting Work instruction Display OK If not OK 1 Check thermostat Step 2. Replace thermostat → End 2 Check coolant shutoff valve in Tiptronic vehicles Step 3. Replace coolant shutoff valve in Tip- tronic vehicles → End 2462 P0116 0-15.1 page 1 Printed in Germany – 6, 2002 p0116