Porsche DME 7.8 — OBD II Diagnosis Manual / PAGE 254
DME 7.8 DME 7.8 0 · 0-18.4P0125
Read extracted page text
OCR can contain errors. Check the original page image for exact wording, warnings and specifications.
DME 7.8 DME 7.8 0
0-18.4P0125
Engine Temperature - Open Circuit
Diagnosis conditions
• A fault is recorded after a debounce time of 0.4 seconds if an
engine temperature of less than -45 °C is measured.
Possible fault cause
♦Wiring
♦Temperature sensor faulty
♦DME control module faulty
Affected terminals
Terminal III/22 and III/17
Resistance values
0 °C 5.0 -7.0 kΩ
20 °C 2.0 -3.0 kΩ
60 °C 0,4 -0,8 kΩ
Diagnosis/Troubleshooting
Work instruction Display OK If not OK
1 Check temperature sen- ♦Remove plug connection in Approx. 2 - 3 kΩ Replace tempera-
sor. engine compartment Step 2 ture sensor
→ End ♦Measure resistance between
temperature sensor Pin 1 and
Pin 4
2 Check output voltage of ♦Connect special tool 9637. Do Approx. 5 V Step 3.
DME control module not connect connector III of vehi- → End
cle wiring harness.
♦Measure voltage between Pin III/
22 and III/17
♦Ignition on
2462 P0125 0-18.4 page 1
Printed in Germany – 6, 2002 p0125