Porsche DME 7.8 — OBD II Diagnosis Manual / PAGE 351

DME 7.8 DME 7.80 · Work instruction Display OK

Add to repair workspace
Open repair workspace
Open full manual Original source
Original manual page 351
Read extracted page text

OCR can contain errors. Check the original page image for exact wording, warnings and specifications.

DME 7.8 DME 7.80 Work instruction Display OK If not OK 3 Check fuel pressure regu- ♦Remove vacuum hose from fuel 0.4 - 0.6 bar Check the intake air lator, vacuum connection pressure regulator system for leaks and fuel return line ♦Connect special tool 9103/2 to and check vacuum line to fuel pressure vacuum hose regulator for restric- ♦Start the engine. tions. ♦ ♦Check housing of fuel pressure Replace the fuel regulator for damage and defor- pressure regulator if mation it is damaged with the result that the spring pre-tension- ing is increased 4 Check EVAP canister ♦Disconnect hose from EVAP can- The vacuum must purge valve ister purge valve to intake sys- not fall below 0.5 tem at EVAP canister purge bar after 10 minutes valve ♦Remove connector of EVAP can- ister purge valve ♦Connect special tool 9160/1 to EVAP canister purge valve ♦Generate vacuum of approx. 0.7 bar 5 Check fuel injectors for leaks 0-36.5 page 2 2469 P0175 p0175 Printed in Germany – 6, 2002

This is a source reference. Confirm exact model applicability in the original material.