DME 7.8 DME 7.8 0 · 0-38P0198

Add to repair workspace
Open repair workspace
Open full manual Original source
Original manual page 354
Read extracted page text

OCR can contain errors. Check the original page image for exact wording, warnings and specifications.

DME 7.8 DME 7.8 0 0-38P0198 125 Oil temperature sensor - above limit Diagnosis conditions • Idle speed • Time elapsed after engine start-up greater than 5 minutes Possible fault cause ♦Temperature sensor faulty ♦Wiring harness ♦DME control module faulty Affected terminals Terminal III/5 and III/17 Resistance values 60 2.8 - 3.5 kΩ °C 90 1.0 - 1.3 kΩ °C 120 0.4 - 0.6 kΩ °C Diagnosis/troubleshooting Work instruction Display OK If not OK 1 Check temperature sen- ♦Connect special tool 9637 to 2.8 - 3.5 kΩ Replace tempera- sor wiring harness (DME control (at 60 °C) ture sensor module plug) ⇒ Step 2 → End ♦Measure resistance between Pin III/17 and Pin III/5 2 Check wiring from DME ♦Connect special tool 9637 to 0 V Repair wiring har- control module to temper- wiring harness (DME control ⇒ Step 3 ness ature sensor for short to module plug) → End B+ ♦Remove plug connection of tem- perature sensor ♦Switch on the ignition ♦Measure voltage between Pin III/ 5 and ground 1709 P0198 0-38 page 1 Printed in Germany, 2000 p0198