Porsche DME 7.8 — OBD II Diagnosis Manual / PAGE 474

DME 7.8 DME 7.80 · 20 21 22 23 24 25 26 27 28 29 s

Add to repair workspace
Open repair workspace
Open full manual Original source
Original manual page 474
Read extracted page text

OCR can contain errors. Check the original page image for exact wording, warnings and specifications.

DME 7.8 DME 7.80 A B 20 21 22 23 24 25 26 27 28 29 s A - Oxygen sensing, bank 1 B - Oxygen sensing, bank 2 1 - Select system test. 2 - Select 'Request large lift'. If "Valve diagnosis not ready" appears, a fault may have been stored. 1. Erase the fault memory. 3 - Activate the system test with the key F8 immediately before acceleration with wide-open throttle. The message "Drive link active" then appears. 4 - Perform acceleration with wide-open throttle in 2nd gear, until "Valve lift diagnosis complete" appears. Note! ♦If a fault is detected, it is only recorded in the fault memory after 6,000 ignitions (at idling speed approx. 3 minutes waiting time). ♦It is important to observe the oxygen sensors during accelera- tion with wide-open throttle or to record their behaviour with the data logger. Continue by performing the system test for small lift 0-49 page 8 2470 P0306 p0306 Printed in Germany – 4, 2002