Porsche DME 7.8 — OBD II Diagnosis Manual / PAGE 474
DME 7.8 DME 7.80 · 20 21 22 23 24 25 26 27 28 29 s
Read extracted page text
OCR can contain errors. Check the original page image for exact wording, warnings and specifications.
DME 7.8 DME 7.80
A
B
20 21 22 23 24 25 26 27 28 29 s
A - Oxygen sensing, bank 1
B - Oxygen sensing, bank 2
1 - Select system test.
2 - Select 'Request large lift'.
If "Valve diagnosis not ready" appears, a fault may have been
stored.
1. Erase the fault memory.
3 - Activate the system test with the key F8 immediately
before acceleration with wide-open throttle.
The message "Drive link active" then appears.
4 - Perform acceleration with wide-open throttle in 2nd
gear, until "Valve lift diagnosis complete" appears.
Note!
♦If a fault is detected, it is only recorded in the fault memory after
6,000 ignitions (at idling speed approx. 3 minutes waiting time).
♦It is important to observe the oxygen sensors during accelera-
tion with wide-open throttle or to record their behaviour with the
data logger.
Continue by performing the system test for small lift
0-49 page 8 2470 P0306
p0306 Printed in Germany – 4, 2002