Porsche DME 7.8 — OBD II Diagnosis Manual / PAGE 497

DME 7.8 DME 7.8 0 · 0-56P0342

Add to repair workspace
Open repair workspace
Open full manual Original source
Original manual page 497
Read extracted page text

OCR can contain errors. Check the original page image for exact wording, warnings and specifications.

DME 7.8 DME 7.8 0 0-56P0342 112 Camshaft position sensor 1 - below limit Diagnosis conditions • Engine running Possible fault cause ♦Short circuit to ground Note! ♦If both CMP sensor signals are missing, the start will take at least 10 seconds. ♦For safety reasons, the ignition timing is retarded. Affected terminals Terminal III/12 Diagnosis/troubleshooting Work instruction Display OK If not OK 1 Check signal wire from ♦Connect special tool 9637 to ∞ Ω Repair wiring har- DME control module, wiring harness (DME control → End ness Pin III/12, to CMP sensor module plug) → End for short to ground ♦Remove connector of CMP sen- sor 1 ♦Measure resistance between special tool 9637 Pin III/12 and ground 2839 P0342 0-56 page 1 Printed in Germany, 2000 p0342