Porsche DME 7.8 — OBD II Diagnosis Manual / PAGE 499
DME 7.8 DME 7.8 0 · 0-57P0343
Read extracted page text
OCR can contain errors. Check the original page image for exact wording, warnings and specifications.
DME 7.8 DME 7.8 0
0-57P0343
112 Camshaft position sensor 1 - above limit
Diagnosis conditions
• Engine running
Possible fault cause
♦Short circuit to B+
Note!
♦If both CMP sensor signals are missing, the start will take at
least 10 seconds.
♦For safety reasons, the ignition timing is retarded.
Affected terminals
Terminal III/12
Diagnosis/troubleshooting
Work instruction Display OK If not OK
1 Check signal wire from ♦Connect special tool 9637 to 0 V Repair wiring har-
DME control module, wiring harness (DME control → End ness
Pin III/12, to CMP sensor module plug) → End
for short to B+ ♦Remove connector of CMP sen-
sor 1
♦Switch on the ignition
♦Measure voltage between spe-
cial tool 9637 Pin III/12 and
ground
2839 P0343 0-57 page 1
Printed in Germany, 2000 p0343
This is a source reference. Confirm exact model applicability in the original material.