fullymatted.
Back to search
Porsche DME 7.8 — OBD II Diagnosis Manual / PAGE 517

DME 7.8 DME 7.8 0 · 0-60P0414

Add to repair workspace
Open repair workspace
Open full manual Original source
Original manual page 517
Read extracted page text

OCR can contain errors. Check the original page image for exact wording, warnings and specifications.

DME 7.8 DME 7.8 0 0-60P0414 85 Electric change-over valve - below limit Diagnosis conditions • Engine running • Battery voltage greater than 7 V Possible fault cause ♦Short circuit to ground Note! The triggering wire for the electric change-over valve is monitored. Affected terminals Terminal III/14 Diagnosis/troubleshooting Work instruction Display OK If not OK 1 Check wire from DME ♦Remove connector of electric ∞ Ω Repair wiring har- control module, Pin III/14, change-over valve → End ness to electric change-over → End ♦Measure resistance between valve for short circuit to DME control module Pin III/14 ground and electric change-over valve plug Pin 2 85 Electric change-over valve - above limit Diagnosis conditions • Engine running • Battery voltage greater than 7 V Possible fault cause ♦Short circuit to B+ Note! The triggering wire for the electric change-over valve is monitored. 2644 P0414 0-60 page 1 Printed in Germany, 2000 p0414

This is a source reference. Confirm exact model applicability in the original material.