Porsche DME 7.8 — OBD II Diagnosis Manual / PAGE 517
DME 7.8 DME 7.8 0 · 0-60P0414
Read extracted page text
OCR can contain errors. Check the original page image for exact wording, warnings and specifications.
DME 7.8 DME 7.8 0
0-60P0414
85 Electric change-over valve - below limit
Diagnosis conditions
• Engine running
• Battery voltage greater than 7 V
Possible fault cause
♦Short circuit to ground
Note!
The triggering wire for the electric change-over valve is monitored.
Affected terminals
Terminal III/14
Diagnosis/troubleshooting
Work instruction Display OK If not OK
1 Check wire from DME ♦Remove connector of electric ∞ Ω Repair wiring har-
control module, Pin III/14, change-over valve → End ness
to electric change-over → End ♦Measure resistance between
valve for short circuit to DME control module Pin III/14
ground and electric change-over valve
plug Pin 2
85 Electric change-over valve - above limit
Diagnosis conditions
• Engine running
• Battery voltage greater than 7 V
Possible fault cause
♦Short circuit to B+
Note!
The triggering wire for the electric change-over valve is monitored.
2644 P0414 0-60 page 1