Porsche DME 7.8 — OBD II Diagnosis Manual / PAGE 520
DME 7.8 DME 7.80 · 84 Secondary air injection pump - below limit
Read extracted page text
OCR can contain errors. Check the original page image for exact wording, warnings and specifications.
DME 7.8 DME 7.80
84 Secondary air injection pump - below limit
Diagnosis conditions
• Engine running
• Battery voltage greater than 7 V
Possible fault cause
♦Short circuit to ground
Affected terminals
Terminal III/11
Diagnosis/troubleshooting
Work instruction Display OK If not OK
1 Check wiring from DME ♦Remove relay for secondary air 0 V Repair wiring har-
control module, Pin III/11, injection pump → End ness
to relay of secondary air → End ♦Measure voltage between DME
injection pump Pin 85 for control module Pin III/11 and B+
short to ground
♦Switch on the ignition
84 Secondary air injection pump - above limit
Diagnosis conditions
• Engine running
• Battery voltage greater than 7 V
Possible fault cause
♦Short circuit to B+
Affected terminals
Terminal III/11
0-61 page 2 2665 P0418
p0418 Printed in Germany, 2000
This is a source reference. Confirm exact model applicability in the original material.