DME 7.8 DME 7.8 0 · 0-62P0420

Add to repair workspace
Open repair workspace
Open full manual Original source
Original manual page 523
Read extracted page text

OCR can contain errors. Check the original page image for exact wording, warnings and specifications.

DME 7.8 DME 7.8 0 0-62P0420 40 TWC conversion, bank 1 - above limit Diagnosis conditions • TWC temperature 420 - 600 °C • 85 seconds within rpm/load range (cumulative) • EVAP canister burden < 8 • Speed 1280 - 2440 rpm • 20 - 40 % engine load (relative air charge) • Oxygen sensing ahead of TWC is active • Oxygen sensing after TWC ready for operation • Engine starting temperature > - 20 °C • No faults in memory Possible fault cause ♦Oxygen sensor ahead of and after TWC exchanged ♦Valve lift fault ♦Aged oxygen sensor after TWC ♦TWC faulty Affected terminals - Diagnosis/troubleshooting Note! If an ageing oxygen sensor is recorded in conjunction with a fault in the TWC, a check must be performed with a new oxygen sensor to see whether a TWC fault is still indicated. Work instruction Display OK If not OK 1 Check whether the oxy- gen sensors ahead of and after the TWC have been exchanged 2673 P0420 0-62 page 1 Printed in Germany, 2000 p0420