Porsche DME 7.8 — OBD II Diagnosis Manual / PAGE 527
DME 7.8 DME 7.8 0 · 0-63P0430
Read extracted page text
OCR can contain errors. Check the original page image for exact wording, warnings and specifications.
DME 7.8 DME 7.8 0
0-63P0430
45 TWC Conversion, Bank 2 - Above Limit
Diagnosis conditions
• TWC temperature 420 - 600 °C
• 85 seconds within rpm/load range (cumulative)
• EVAP canister burden < 8
• Speed 1280 - 2440 rpm
• 20 - 40 % engine load (relative air charge)
• Oxygen sensing ahead of TWC is active
• Oxygen sensing after TWC ready for operation
• Engine starting temperature > - 20 °C
• No faults in memory
Possible fault cause
♦Oxygen sensor ahead of and after TWC exchanged
♦Valve lift fault
♦Aged oxygen sensor after TWC
♦TWC faulty
Affected terminals
-
Diagnosis/troubleshooting
Note!
If an ageing oxygen sensor is recorded in conjunction with a fault in the TWC, a check must be performed with a
new oxygen sensor to see whether a TWC fault is still indicated.
Work instruction Display OK If not OK
1 Check whether the oxy-
gen sensors ahead of and
after the TWC have been
exchanged
2673 P0430 0-63 page 1
Printed in Germany – 1, 2000 p0430