Porsche DME 7.8 — OBD II Diagnosis Manual / PAGE 567

DME 7.8 DME 7.8 0 · 94 Fuel Tank Ventilation System (Major Leak) - Signa

Add to repair workspace
Open repair workspace
Open full manual Original source
Original manual page 567
Read extracted page text

OCR can contain errors. Check the original page image for exact wording, warnings and specifications.

DME 7.8 DME 7.8 0 94 Fuel Tank Ventilation System (Major Leak) - Signal Implausible Diagnosis conditions • Oxygen sensing system active • No secondary air diagnosis • Engine running • Vehicle speed = 0 km/h • Intake air temperature between 4.5 °C and 60 °C • Battery positive voltage greater than 11 V • Engine load less than 30% • EVAP canister burden less than 3 • Altitude correction factor greater than 0.75 • Time elapsed after engine start-up > 990 seconds or mixture adaptation completed • No faults in memory Possible fault cause ♦Pressure sensor Affected terminals - Diagnosis/troubleshooting Note! Fuel tank ventilation diagnosis is initiated with the Porsche System Tester 2 in the "Short test" menu. This reduces the time elapsed after engine start-up to 30 seconds. Work instruction Display OK If not OK 1 Replace pressure sensor 2023 P0455 0-75 page 3 Printed in Germany – 1, 2000 p0455