Porsche DME 7.8 — OBD II Diagnosis Manual / PAGE 567
DME 7.8 DME 7.8 0 · 94 Fuel Tank Ventilation System (Major Leak) - Signa
Read extracted page text
OCR can contain errors. Check the original page image for exact wording, warnings and specifications.
DME 7.8 DME 7.8 0
94 Fuel Tank Ventilation System (Major Leak) - Signal
Implausible
Diagnosis conditions
• Oxygen sensing system active
• No secondary air diagnosis
• Engine running
• Vehicle speed = 0 km/h
• Intake air temperature between 4.5 °C and 60 °C
• Battery positive voltage greater than 11 V
• Engine load less than 30%
• EVAP canister burden less than 3
• Altitude correction factor greater than 0.75
• Time elapsed after engine start-up > 990 seconds or mixture
adaptation completed
• No faults in memory
Possible fault cause
♦Pressure sensor
Affected terminals
-
Diagnosis/troubleshooting
Note!
Fuel tank ventilation diagnosis is initiated with the Porsche System Tester 2 in the "Short test" menu. This reduces
the time elapsed after engine start-up to 30 seconds.
Work instruction Display OK If not OK
1 Replace pressure sensor
2023 P0455 0-75 page 3
Printed in Germany – 1, 2000 p0455