Porsche DME 7.8 — OBD II Diagnosis Manual / PAGE 576
DME 7.8 DME 7.80 · Work instruction Display OK
Read extracted page text
OCR can contain errors. Check the original page image for exact wording, warnings and specifications.
DME 7.8 DME 7.80
Work instruction Display OK If not OK
♦Measure resistance between 0 - 5 Ω Check plug connec-
special tool 9637 plug IV Pin 4 ⇒ Step 3 tion X 2/3, Pin 21,
and relay slot of coolant fan 2 and check wiring
plug Pin 2 harness for chafing
and pinching dam-
age
3 Replace DME control module ⇒ Step 4
4 Perform adaptation ♦Switch on the ignition → End
♦Wait one minute
♦Do not press the accelerator
♦Switch off the ignition for at
least 10 seconds
♦Read out the fault memory
494 Fan output stage 1 - below limit
Diagnosis conditions
• Engine running
• Battery voltage greater than 7 V
• Intake air temperature greater than 9 °C
• Air conditioning switched on and off once
Note!
The triggering wire for relays stage 1, terminal 85, is monitored
Possible fault cause
♦Short circuit to ground
♦Relay faulty
♦DME control module faulty
Affected terminals
Terminal IV/4
0-76 page 2 1908 P0480
p0480 Printed in Germany, 2000
This is a source reference. Confirm exact model applicability in the original material.