fullymatted.
Back to search
Porsche DME 7.8 — OBD II Diagnosis Manual / PAGE 580

DME 7.8 DME 7.80 · Work instruction Display OK

Add to repair workspace
Open repair workspace
Open full manual Original source
Original manual page 580
Read extracted page text

OCR can contain errors. Check the original page image for exact wording, warnings and specifications.

DME 7.8 DME 7.80 Work instruction Display OK If not OK ♦Measure resistance between 0 - 5 Ω Check plug connec- special tool 9637 plug IV Pin 20 ⇒ Step 3 tion X 2/3, Pin 22, and relay slot of coolant fan 2 and check wiring plug Pin 2 harness for chafing and pinching dam- age 3 Replace DME control module ⇒ Step 4 4 Perform adaptation ♦Switch on the ignition → End ♦Wait one minute ♦Do not press the accelerator ♦Switch off the ignition for at least 10 seconds ♦Read out the fault memory 495 Fan output stage 2 - below limit Diagnosis conditions • Engine running • Battery voltage greater than 7 V • Medium pressure switch (air conditioning) active or engine tem- perature greater than 105 °C • Air conditioning switched on and off once Note! The triggering wire for relays stage 2, terminal 85, is monitored Possible fault cause ♦Short circuit to ground ♦Relay faulty ♦DME control module faulty Affected terminals Terminal IV/20 0-77 page 2 1908 P0481 p0481 Printed in Germany, 2000

This is a source reference. Confirm exact model applicability in the original material.