Porsche DME 7.8 — OBD II Diagnosis Manual / PAGE 605
DME 7.8 DME 7.8 0 · 0-82P0560
Read extracted page text
OCR can contain errors. Check the original page image for exact wording, warnings and specifications.
DME 7.8 DME 7.8 0
0-82P0560
107 Voltage supply - signal implausible
Diagnosis conditions
• Vehicle speed greater than 0 km/h (0 mph)
• No fault in vehicle speed
• Time elapsed after start-up 60 sec.
Possible fault cause
♦DME control module
Affected terminals
Terminal II/2
Diagnosis/troubleshooting
Note!
In case of a fault, a replacement value of 14.06 V is used.
Work instruction Display OK If not OK
1 Replace DME control module ⇒ Step 2
2 Perform adaptation ♦Switch on the ignition → End → End
♦Wait one minute
♦Do not press the accelerator
♦Switch off the ignition for at
least 10 seconds
♦Read out the fault memory
2706 P0560 0-82 page 1
Printed in Germany, 2000 p0560