Porsche DME 7.8 — OBD II Diagnosis Manual / PAGE 607

DME 7.8 DME 7.8 0 · 0-83P0562

Add to repair workspace
Open repair workspace
Open full manual Original source
Original manual page 607
Read extracted page text

OCR can contain errors. Check the original page image for exact wording, warnings and specifications.

DME 7.8 DME 7.8 0 0-83P0562 107 Voltage supply - below limit Diagnosis conditions • Vehicle speed greater than 0 km/h (0 mph) • No fault in vehicle speed • Time elapsed after start-up 60 sec. Possible fault cause ♦Battery ♦Contact resistance Affected terminals Terminal II/2 Diagnosis/troubleshooting Work instruction Display OK If not OK 1 Check battery ⇒ Step 2 Replace battery → End 2 Check wire, terminal 30, ♦Connect special tool 9637 to > 11 V ⇒ Step 3 for contact resistance wiring harness (DME control ⇒ Step 4 module plug) ♦Measure voltage between spe- cial tool 9637 Pin I/2 and ground 3 ♦Check wire from special tool 0 - 5 Ω 9637, Pin I/2, to pin side of con- ⇒ Step 4 nector X 2/3, Pin 2, for continu- ity ♦Check connector for corrosion 4 ♦Check wire from connector X 2/ 0 - 5Ω Remedy contact 3, sleeve side, to current distrib- ⇒ Step 5 resistance utor fuse C 1 for continuity → End 5 Check voltage regulator and alternator → End 2706 P0562 0-83 page 1 Printed in Germany, 2000 p0562