DME 7.8 DME 7.8 0 0-P0601P0601 DME relay/control module faulty (computer monitor- ing: reset) – signal implausible Diagnosis conditions • Time elapsed after engine start-up greater than 10 seconds Possible fault cause ♦Undervoltage ♦DME relay faulty ♦DME control module faulty (checksum error caused by tamper- ing with data record) Affected terminals - Diagnosis/troubleshooting Work instruction Display OK If not OK 1 Check voltage supply, ter- ♦Measure voltage between pin I/ > 11 V Check voltage sup- minal 15 1 and ground. ply and repair if nec- essary → End 2 Check DME relay ♦Switch on the ignition Battery positive volt- Check triggering of age DME relay ♦Measure voltage between pin I/ Repair wiring or 8 and ground replace DME relay → End 3 Replace DME control module ⇒ Step 4 4 Perform adaptation. ♦Switch on the ignition → End ♦Wait one minute ♦Do not press the accelerator ♦Switch off the ignition for at least 10 seconds ♦Read out the fault memory 2470 P0601 0-P0601 page 1 Printed in Germany – 13, 2003 p0601