Porsche DME 7.8 — OBD II Diagnosis Manual / PAGE 629
DME 7.8 DME 7.8 0 · 0-88.4P0646
Read extracted page text
OCR can contain errors. Check the original page image for exact wording, warnings and specifications.
DME 7.8 DME 7.8 0
0-88.4P0646
A/C Compressor Control – Below Limit
Diagnosis conditions
• Engine running
• Battery positive voltage greater than 7 V
• Air conditioning on
Possible fault cause
♦Short circuit to ground in wiring
Affected terminals
Terminal IV/27
Diagnosis/Troubleshooting
Work instruction Display OK If not OK
1 Check control wire for A/ ♦Remove A/C relay ∞ Ω Repair wiring har-
C relay, Pin 2 (terminal → End. ness ♦Remove DME control module
85), for short circuit to → End. connector
ground
♦Measure resistance between Pin
2 (terminal 85) and ground
8728 P0646 0-88.4 page 1
Printed in Germany – 6, 2002 p0646
This is a source reference. Confirm exact model applicability in the original material.