Porsche DME 7.8 — OBD II Diagnosis Manual / PAGE 633
DME 7.8 DME 7.8 0 · 0-89.1P0674
Read extracted page text
OCR can contain errors. Check the original page image for exact wording, warnings and specifications.
DME 7.8 DME 7.8 0
0-89.1P0674
A/C Compressor Control – Above Limit
Diagnosis conditions
• Engine running
• Battery positive voltage greater than 7 V
• Air conditioning on
Possible fault cause
♦Short circuit to B+ in wiring
Affected terminals
Terminal IV/27
Diagnosis/Troubleshooting
Work instruction Display OK If not OK
1 Check control wire for A/ ♦Remove A/C relay 0 V Repair wiring har-
C relay, Pin 2 (terminal → End. ness ♦Remove DME control module
85), for short circuit to → End. connector
B+
♦Measure voltage between A/C
relay Pin 2 and ground
♦Ignition on
8728 P0674 0-89.1 page 1
Printed in Germany – 6, 2002 p0674