fullymatted.
Back to search
Porsche DME 7.8 — OBD II Diagnosis Manual / PAGE 633

DME 7.8 DME 7.8 0 · 0-89.1P0674

Add to repair workspace
Open repair workspace
Open full manual Original source
Original manual page 633
Read extracted page text

OCR can contain errors. Check the original page image for exact wording, warnings and specifications.

DME 7.8 DME 7.8 0 0-89.1P0674 A/C Compressor Control – Above Limit Diagnosis conditions • Engine running • Battery positive voltage greater than 7 V • Air conditioning on Possible fault cause ♦Short circuit to B+ in wiring Affected terminals Terminal IV/27 Diagnosis/Troubleshooting Work instruction Display OK If not OK 1 Check control wire for A/ ♦Remove A/C relay 0 V Repair wiring har- C relay, Pin 2 (terminal → End. ness ♦Remove DME control module 85), for short circuit to → End. connector B+ ♦Measure voltage between A/C relay Pin 2 and ground ♦Ignition on 8728 P0674 0-89.1 page 1 Printed in Germany – 6, 2002 p0674

This is a source reference. Confirm exact model applicability in the original material.