fullymatted.
Back to search
Porsche DME 7.8 — OBD II Diagnosis Manual / PAGE 640

DME 7.8 DME 7.80 · P code Fault code Fault text Fault effect

Add to repair workspace
Open repair workspace
Open full manual Original source
Original manual page 640
Read extracted page text

OCR can contain errors. Check the original page image for exact wording, warnings and specifications.

DME 7.8 DME 7.80 P code Fault code Fault text Fault effect P0702 56 Control unit fault - encoding error (EEP- Control unit in limp home mode, mini- ROM: Version invalid) mum cycle initiated 57 Control unit faulty (clock) Control unit in limp home mode, CAN Off 58 Control unit fault (test of internal watch- Control unit in limp home mode, mini- dog) mum cycle initiated 59 Control unit fault (test of external Control unit in limp home mode, mini- watchdog) mum cycle initiated 62 Control unit faulty (RAM) Control unit in limp home mode, mini- mum cycle initiated, CAN Off 63 Control unit faulty (ROM) Control unit in limp home mode, mini- mum cycle initiated, CAN Off 64 Control unit faulty (EEPROM function Control unit in limp home mode, mini- critical) mum cycle initiated 0-P0702 page 2 2470 P0702 p0702 Printed in Germany – 14, 2003

This is a source reference. Confirm exact model applicability in the original material.