Porsche DME 7.8 — OBD II Diagnosis Manual / PAGE 643

DME 7.8 DME 7.8 0 · 0-95P0712

Add to repair workspace
Open repair workspace
Open full manual Original source
Original manual page 643
Read extracted page text

OCR can contain errors. Check the original page image for exact wording, warnings and specifications.

DME 7.8 DME 7.8 0 0-95P0712 Transmission Oil Temperature - Below Limit Diagnosis conditions • Idle speed Possible fault cause ♦Temperature sensor faulty ♦Wiring harness ♦DME control module faulty Affected terminals Terminal II/23 and IV/11 Resistance values 60 2.8 -3.5 kΩ °C 90 1.0 -1.3 kΩ °C 120 0.4 -0.6 kΩ °C Diagnosis/Troubleshooting Work instruction Display OK If not OK 1 Check temperature sen- ♦Connect special tool 9637 to 2.8 - 3.5 kΩ Replace tempera- sor wiring harness (DME control (at 60 °C) ture sensor module plug). Step 2 → End ♦Measure resistance between Pin II/23 and Pin IV/11 2 Check wiring from DME ♦Connect special tool 9637 to 0 - 5 Ω Note control module to temper- wiring harness (DME control Step 3. The lines are routed ature sensor for continu- module plug). via the transmis- ity ♦Remove plug connection of tem- sion plug connec- tion perature sensor Repair wiring har- ♦Measure resistance between ness special tool 9637 Pin II/23 and → End temperature sensor plug Pin 2 ♦Measure resistance between special tool 9637 Pin IV/11 and temperature sensor plug Pin 1 3478 P0712 0-95 page 1 Printed in Germany – 6, 2002 p0712

This is a source reference. Confirm exact model applicability in the original material.