Porsche DME 7.8 — OBD II Diagnosis Manual / PAGE 645

DME 7.8 DME 7.8 0 · 0-96P0713

Add to repair workspace
Open repair workspace
Open full manual Original source
Original manual page 645
Read extracted page text

OCR can contain errors. Check the original page image for exact wording, warnings and specifications.

DME 7.8 DME 7.8 0 0-96P0713 Transmission Oil Temperature - Above Limit Diagnosis conditions • Idle speed Possible fault cause ♦Temperature sensor faulty ♦Wiring harness ♦DME control module faulty Affected terminals Terminal II/23 and IV/11 Resistance values 60 2.8 -3.5 kΩ °C 90 1.0 -1.3 kΩ °C 120 0.4 -0.6 kΩ °C Diagnosis/Troubleshooting Work instruction Display OK If not OK 1 Check temperature sen- ♦Connect special tool 9637 to 2.8 - 3.5 kΩ Replace tempera- sor. wiring harness (DME control (at 60 °C) ture sensor module plug). Step 2 → End ♦Measure resistance between Pin II/23 and Pin IV/11 2 Check wiring from DME ♦Connect special tool 9637 to 0 V Repair wiring har- control module to temper- wiring harness (DME control Step 3. ness ature sensor for short to module plug). → End. B+ ♦Remove plug connection of tem- perature sensor ♦Switch on the ignition. ♦Measure voltage between pin IV/ 11 and ground. 3478 P0713 0-96 page 1 Printed in Germany – 6, 2002 p0713