Ambient Pressure Sensor – Above Limit
Diagnosis conditions
• Ignition on
Possible fault cause
♦DME control module
Affected terminals
-
Diagnosis/Troubleshooting
Note!
If no fault is present, erase the fault memory.
Work instruction Display OK If not OK
1 Replace DME control
module.
2 Perform adaptation. ♦Switch on the ignition.
♦Wait one minute.
♦Do not press the accelerator.
♦Switch off the ignition for at
least 10 seconds.
♦Read out the fault memory.