DME 7.8 DME 7.8 0 · 0-103P1110

Add to repair workspace
Open repair workspace
Open full manual Original source
Original manual page 681
Read extracted page text

OCR can contain errors. Check the original page image for exact wording, warnings and specifications.

DME 7.8 DME 7.8 0 0-103P1110 294 Oxygen Sensors Exchanged Ahead of TWC Diagnosis conditions • Engine at operating temperature • Oxygen sensing system active Possible fault cause ♦Wiring harness Affected terminals II/15 and II/16 Diagnosis/Troubleshooting Note! When the oxygen sensors are exchanged, then the oxygen sensors run contrary to the adaptation limitation. Work instruction Display OK If not OK 1 Check wiring harness ♦Measure resistance between 0 - 5 Ω Repair wiring har- oxygen sensor connector 1 pin ness 1 and DME control module con- nector pin II/15 2 ♦Measure resistance between 0 - 5 Ω Repair wiring har- oxygen sensor connector 2 pin ness 1 and DME control module con- nector pin II/16 P1110 0-103 page 1 Printed in Germany – 2, 2000 p1110