fullymatted.
Back to search
Porsche DME 7.8 — OBD II Diagnosis Manual / PAGE 687

DME 7.8 DME 7.8 0 · 0-105P1115

Add to repair workspace
Open repair workspace
Open full manual Original source
Original manual page 687
Read extracted page text

OCR can contain errors. Check the original page image for exact wording, warnings and specifications.

DME 7.8 DME 7.8 0 0-105P1115 13 Oxygen Sensor Ahead of TWC, Bank 1 – Signal Implausible Diagnosis conditions • Mass air flow above 32 kg/h • No other oxygen sensor faults • Battery voltage between 9.5 V and 16 V Possible fault cause ♦Open circuit ♦Oxygen sensor heating faulty ♦DME control module Affected terminals II/19 Diagnosis/Troubleshooting Note! Do not use contact spray on the connectors to oxygen sensor. Work instruction Display OK If not OK 1 Check connector for cor- ♦Visual inspection rosion 2 Check oxygen sensor ♦Remove oxygen sensor connec- 3.0 to 3.5 Ω at 20 Replace oxygen heating tor ahead of catalytic converter °C sensor Bank 1 ♦Check resistance between pin 3 and 4 towards the oxygen sen- sor 2469 P1115 0-105 page 1 Printed in Germany – 2, 2000 p1115

This is a source reference. Confirm exact model applicability in the original material.