Porsche DME 7.8 — OBD II Diagnosis Manual / PAGE 692
DME 7.8 DME 7.80 · Do not use contact spray on the connectors to oxygen sensor.
Read extracted page text
OCR can contain errors. Check the original page image for exact wording, warnings and specifications.
DME 7.8 DME 7.80
Note!
Do not use contact spray on the connectors to oxygen sensor.
Work instruction Display OK If not OK
1 Check oxygen sensor ♦Remove oxygen sensor connec- 3.0 to 3.5 Ω at 20 Replace oxygen
heating tor Bank 1 ahead of catalytic °C sensor
converter
♦Check resistance between pin 3
and 4 towards the oxygen sen-
sor
♦
2 ♦Check resistance between pin 4 ∞ Ω
and the oxygen sensor housing
3 Check wiring ♦Check resistance between pin 4 ∞ Ω Repair wiring har-
and vehicle ground towards ness
DME control module
Note!
Do not exchange oxygen sensors ahead of catalytic converter and
after catalytic converter.
0-105 page 6 2469 P1115
p1115 Printed in Germany – 2, 2000