Porsche DME 7.8 — OBD II Diagnosis Manual / PAGE 779
DME 7.8 DME 7.8 0 · Work instruction
Read extracted page text
OCR can contain errors. Check the original page image for exact wording, warnings and specifications.
DME 7.8 DME 7.8 0
Work instruction Display OK If not OK
♦Measure resistance between 0 - 5 Ω
disconnection point Pin 1 and
special tool 9637 Pin I/9
♦Measure resistance between 0 - 5 Ω
disconnection point Pin 2 and
special tool 9637 Pin III/25
♦Measure resistance between 0 - 5 Ω
disconnection point Pin 3 and
special tool 9637 Pin III/10
♦Measure resistance between 0 - 5 Ω
disconnection point Pin 4 and
special tool 9637 Pin I/7
♦Measure resistance between 0 - 5 Ω
disconnection point Pin 5 and
special tool 9637 Pin III/8
♦Measure resistance between Pin ∞ Ω
4 and ground
♦Measure resistance between ∞ Ω
disconnection point Pin 5 and
ground
2442 P1141 0-122.4 page 3
Printed in Germany – 6, 2002 p1141
This is a source reference. Confirm exact model applicability in the original material.