Porsche DME 7.8 — OBD II Diagnosis Manual / PAGE 779

DME 7.8 DME 7.8 0 · Work instruction

Add to repair workspace
Open repair workspace
Open full manual Original source
Original manual page 779
Read extracted page text

OCR can contain errors. Check the original page image for exact wording, warnings and specifications.

DME 7.8 DME 7.8 0 Work instruction Display OK If not OK ♦Measure resistance between 0 - 5 Ω disconnection point Pin 1 and special tool 9637 Pin I/9 ♦Measure resistance between 0 - 5 Ω disconnection point Pin 2 and special tool 9637 Pin III/25 ♦Measure resistance between 0 - 5 Ω disconnection point Pin 3 and special tool 9637 Pin III/10 ♦Measure resistance between 0 - 5 Ω disconnection point Pin 4 and special tool 9637 Pin I/7 ♦Measure resistance between 0 - 5 Ω disconnection point Pin 5 and special tool 9637 Pin III/8 ♦Measure resistance between Pin ∞ Ω 4 and ground ♦Measure resistance between ∞ Ω disconnection point Pin 5 and ground 2442 P1141 0-122.4 page 3 Printed in Germany – 6, 2002 p1141