DME 7.8 DME 7.8 0 · 0-122.10P1156

Add to repair workspace
Open repair workspace
Open full manual Original source
Original manual page 795
Read extracted page text

OCR can contain errors. Check the original page image for exact wording, warnings and specifications.

DME 7.8 DME 7.8 0 0-122.10P1156 Oxygen Sensor Ahead of TWC, Bank 2 – Open Circuit Diagnosis conditions • Vehicle at operating temperature, after this 3 minutes idle speed, then approx. 30 seconds increased idle speed. Possible fault cause ♦Oxygen sensors (heating connection) Affected terminals - Diagnosis/Troubleshooting Note! Do not use contact spray on the connectors to oxygen sensor. Work instruction Display OK If not OK 1 Replace oxygen sensor Note! Do not exchange oxygen sensors ahead of catalytic converter and after catalytic converter. 2469 P1156 0-122.10 page 1 Printed in Germany – 6, 2002 p1156