Porsche DME 7.8 — OBD II Diagnosis Manual / PAGE 878
DME 7.8 DME 7.80 · 189 Camshaft Adjustment, Bank 1 Output Stage -
Read extracted page text
OCR can contain errors. Check the original page image for exact wording, warnings and specifications.
DME 7.8 DME 7.80
189 Camshaft Adjustment, Bank 1 Output Stage -
Below Limit
Diagnosis conditions
• Engine running
Possible fault cause
♦Short to ground triggering wire
♦Solenoid hydraulic valve faulty
Affected terminals
V/7
Diagnosis/Troubleshooting
Work instruction Display OK If not OK
1 Check triggering wire for ♦Connect special tool 9637 to ∞ Ω
short to ground wiring harness (DME control
module plug)
♦Remove connector of the sole-
noid hydraulic valve
♦Measure resistance between V/
7 and ground
2 Replace solenoid hydrau-
lic valve
189 Camshaft Adjustment, Bank 1 Output Stage -
Above Limit
Diagnosis conditions
• Engine running
Possible fault cause
♦Short circuit to B+ triggering wire
Affected terminals
V/7
0-152 page 2 1536 P1342
p1342 Printed in Germany – 2, 2000
This is a source reference. Confirm exact model applicability in the original material.