Porsche DME 7.8 — OBD II Diagnosis Manual / PAGE 886
DME 7.8 DME 7.80 · 579 Valve Lift Control, Bank 1, Output Stage - Below
Read extracted page text
OCR can contain errors. Check the original page image for exact wording, warnings and specifications.
DME 7.8 DME 7.80
579 Valve Lift Control, Bank 1, Output Stage - Below
Limit
Diagnosis conditions
• Engine running
Possible fault cause
♦Short to ground triggering wire
♦Solenoid hydraulic valve faulty
Affected terminals
III/1
Diagnosis/Troubleshooting
Work instruction Display OK If not OK
1 Check triggering wire for ♦Connect special tool 9637 to ∞ Ω
short to ground wiring harness (DME control
module plug)
♦Remove connector of the sole-
noid hydraulic valve
♦Measure resistance between III/
1 and ground
2 Replace solenoid hydrau-
lic valve
579 Valve Lift Control, Bank 1, Output Stage - Above
Limit
Diagnosis conditions
• Engine running
Possible fault cause
♦Short circuit to B+ triggering wire
Affected terminals
III/1
0-154 page 2 3755 P1344
p1344 Printed in Germany – 2, 2000