Porsche DME 7.8 — OBD II Diagnosis Manual / PAGE 904
DME 7.8 DME 7.80 · ence from the other oxygen sensor > approx. 15 %. In the case of a
Read extracted page text
OCR can contain errors. Check the original page image for exact wording, warnings and specifications.
DME 7.8 DME 7.80
ence from the other oxygen sensor > approx. 15 %. In the case of a
fault, the flat-base tappets of the inlet valves for the entire cylinder
bank must be replaced.
A
B
A - Oxygen sensor, bank 1
B - Oxygen sensor, bank 2
1 - Select system test.
2 - Select ’Request small lift’.
If "Valve lift diagnosis not ready" appears, a fault may have
been stored.
1. Erase the fault memory.
3 - Activate the system test with the key F8 immediately
before acceleration with wide-open throttle.
The message "Drive link active" then appears.
Note!
If ’Request small lift’ appears, the valves remain at small lift, ie.
the performance is reduced dramatically.
4 - Perform acceleration with wide-open throttle in 2nd
gear, until "Valve lift diagnosis complete" (max. 4,000
rpm) appears.
0-156 page 8 1555 P1350
p1350 Printed in Germany, 2000
This is a source reference. Confirm exact model applicability in the original material.