fullymatted.
Back to search
Porsche DME 7.8 — OBD II Diagnosis Manual / PAGE 904

DME 7.8 DME 7.80 · ence from the other oxygen sensor > approx. 15 %. In the case of a

Add to repair workspace
Open repair workspace
Open full manual Original source
Original manual page 904
Read extracted page text

OCR can contain errors. Check the original page image for exact wording, warnings and specifications.

DME 7.8 DME 7.80 ence from the other oxygen sensor > approx. 15 %. In the case of a fault, the flat-base tappets of the inlet valves for the entire cylinder bank must be replaced. A B A - Oxygen sensor, bank 1 B - Oxygen sensor, bank 2 1 - Select system test. 2 - Select ’Request small lift’. If "Valve lift diagnosis not ready" appears, a fault may have been stored. 1. Erase the fault memory. 3 - Activate the system test with the key F8 immediately before acceleration with wide-open throttle. The message "Drive link active" then appears. Note! If ’Request small lift’ appears, the valves remain at small lift, ie. the performance is reduced dramatically. 4 - Perform acceleration with wide-open throttle in 2nd gear, until "Valve lift diagnosis complete" (max. 4,000 rpm) appears. 0-156 page 8 1555 P1350 p1350 Printed in Germany, 2000