Porsche DME 7.8 — OBD II Diagnosis Manual / PAGE 911
DME 7.8 DME 7.80 · A faulty flat-base tappet can be detected because the oxygen sen-
Read extracted page text
OCR can contain errors. Check the original page image for exact wording, warnings and specifications.
DME 7.8 DME 7.80
A faulty flat-base tappet can be detected because the oxygen sen-
sor FR for this cylinder bank enriches the mixture (FR > 1) during
acceleration with wide-open throttle ⇒ see drawing below. Differ-
ence from the other oxygen sensor > approx. 15 %. In the case of a
fault, the flat-base tappets of the inlet valves for the entire cylinder
bank must be replaced.
A
B
A - Oxygen sensor, bank 1
B - Oxygen sensor, bank 2
1 - Select system test.
2 - Select ’Request small lift’.
If "Valve lift diagnosis not ready" appears, a fault may have
been stored.
1. Erase the fault memory.
3 - Activate the system test with the key F8 immediately
before acceleration with wide-open throttle.
The message "Drive link active" then appears.
Note!
If ’Request small lift’ appears, the valves remain at small lift, ie.
the performance is reduced dramatically.
0-157 page 4 1555 P1351
p1351 Printed in Germany, 2000