Porsche DME 7.8 — OBD II Diagnosis Manual / PAGE 1009

DME 7.8 DME 7.8 0 · 0-169P1456

Add to repair workspace
Open repair workspace
Open full manual Original source
Original manual page 1009
Read extracted page text

OCR can contain errors. Check the original page image for exact wording, warnings and specifications.

DME 7.8 DME 7.8 0 0-169P1456 170 A/C compressor control - above limit Diagnosis conditions • Engine running • Battery voltage greater than 7 V • Air conditioning on Possible fault cause ♦Short circuit to B+ in wiring Affected terminals Terminal IV/27 Diagnosis/troubleshooting Work instruction Display OK If not OK 1 Check control wire for A/ ♦Remove A/C relay 0 V Repair wiring har- C relay, Pin 2 (terminal → End ness ♦Remove DME control module 85), for short circuit to → End connector B+ ♦Measure voltage between A/C relay Pin 2 and ground ♦Ignition on 8728 P1456 0-169 page 1 Printed in Germany, 2000 p1456