0-169P1456
170 A/C compressor control - above limit
Diagnosis conditions
• Engine running
• Battery voltage greater than 7 V
• Air conditioning on
Possible fault cause
♦Short circuit to B+ in wiring
Affected terminals
Terminal IV/27
Diagnosis/troubleshooting
Work instruction Display OK If not OK
1 Check control wire for A/ ♦Remove A/C relay 0 V Repair wiring har-
C relay, Pin 2 (terminal → End ness ♦Remove DME control module
85), for short circuit to → End connector
B+
♦Measure voltage between A/C
relay Pin 2 and ground
♦Ignition on
8728 P1456 0-169 page 1
Printed in Germany, 2000 p1456