DME 7.8 DME 7.8 0 0-182P1512 76 Ambient Temperature (via CAN from instrument cluster) - Signal Implausible Diagnosis conditions • Ignition on Possible fault cause ♦Instrument cluster Affected terminals Diagnosis/Troubleshooting Note! With an outside temperature of less than or equal to -40° C, this fault is stored because no lower temperatures can be displayed in the instrument cluster. In this case, a fault status is not present. Work instruction Display OK If not OK 1 Replace instrument clus- ter. 9025 P1512 0-182 page 1 Printed in Germany – 3, 2001 p1512