fullymatted.
Back to search
Porsche DME 7.8 — OBD II Diagnosis Manual / PAGE 1059

DME 7.8 DME 7.8 0 · 0-188P1570

Add to repair workspace
Open repair workspace
Open full manual Original source
Original manual page 1059
Read extracted page text

OCR can contain errors. Check the original page image for exact wording, warnings and specifications.

DME 7.8 DME 7.8 0 0-188P1570 39 Immobilizer - signal implausible Diagnosis conditions • Start condition • Motronic reset Possible fault cause ♦Open circuit in wiring between DME control module and alarm system ♦Short circuit to ground or short circuit to B+ ♦Alarm system control module faulty Affected terminals - Diagnosis/troubleshooting Work instruction Display OK If not OK 1 Check signal wire for con- ♦Remove connector I of alarm 0 - 5 Ω ⇒ Step 2 tinuity system control module ⇒ Step 3 ♦Connect special tool 9637 to wiring harness (DME control module plug) ♦Measure resistance between special tool 9637 Pin I/3 and alarm system control module plug Pin I/23 2 Remove connector X 2/3 ♦Measure resistance between 0 - 5 Ω Repair wiring har- plug connection X 2/3 bushing ⇒ Step 3 ness 6 and special tool 9637 Pin I/3 → End ♦Measure resistance between plug connection X 2/3 Pin 6 and alarm system control module plug I Pin 23 9068 P1570 0-188 page 1 Printed in Germany, 2000 p1570

This is a source reference. Confirm exact model applicability in the original material.