Porsche DME 7.8 — OBD II Diagnosis Manual / PAGE 1059
DME 7.8 DME 7.8 0 · 0-188P1570
Read extracted page text
OCR can contain errors. Check the original page image for exact wording, warnings and specifications.
DME 7.8 DME 7.8 0
0-188P1570
39 Immobilizer - signal implausible
Diagnosis conditions
• Start condition
• Motronic reset
Possible fault cause
♦Open circuit in wiring between DME control module and alarm
system
♦Short circuit to ground or short circuit to B+
♦Alarm system control module faulty
Affected terminals
-
Diagnosis/troubleshooting
Work instruction Display OK If not OK
1 Check signal wire for con- ♦Remove connector I of alarm 0 - 5 Ω ⇒ Step 2
tinuity system control module ⇒ Step 3
♦Connect special tool 9637 to
wiring harness (DME control
module plug)
♦Measure resistance between
special tool 9637 Pin I/3 and
alarm system control module
plug Pin I/23
2 Remove connector X 2/3 ♦Measure resistance between 0 - 5 Ω Repair wiring har-
plug connection X 2/3 bushing ⇒ Step 3 ness
6 and special tool 9637 Pin I/3 → End
♦Measure resistance between
plug connection X 2/3 Pin 6 and
alarm system control module
plug I Pin 23
9068 P1570 0-188 page 1
Printed in Germany, 2000 p1570
This is a source reference. Confirm exact model applicability in the original material.
