Porsche DME 7.8 — OBD II Diagnosis Manual / PAGE 1070
DME 7.8 DME 7.80 · Affected terminals
Read extracted page text
OCR can contain errors. Check the original page image for exact wording, warnings and specifications.
DME 7.8 DME 7.80
Affected terminals
Terminal IV/8
Note!
♦The system operates in pedal sensor standby mode, i.e. the
angle of the accelerator pedal is calculated from the residual
position sensor signal.
♦The maximum pedal value is limited to 30 %.
♦The dynamic is limited.
Diagnosis/troubleshooting
Work instruction Display OK If not OK
1 Check wiring from DME ♦Connect special tool 9637 to ∞ Ω Repair wiring har-
control module, Pin IV/8, wiring harness (DME control ⇒ Step 2 ness
to pedal sensor, Pin 2, for module plug) → End
short circuit to ground ♦Measure resistance between
special tool Pin IV/8 and ground
2 Replace pedal sensor → End → End
427 Accelerator pedal position sensor 1 - above limit
Diagnosis conditions
• Ignition on (approx. 30 sec.)
• Battery voltage greater than 7 V
Possible fault cause
♦Short circuit to B+
♦Pedal sensor
Affected terminals
Terminal IV/8
Note!
♦The system operates in pedal sensor standby mode, i.e. the
angle of the accelerator pedal is calculated from the residual
position sensor signal.
♦The maximum pedal value is limited to 30 %.
♦The dynamic is limited.
0-192 page 2 2078 P1577
p1577 Printed in Germany, 2000