fullymatted.
Back to search
Porsche DME 7.8 — OBD II Diagnosis Manual / PAGE 1079

DME 7.8 DME 7.8 0 · 0-195P1600

Add to repair workspace
Open repair workspace
Open full manual Original source
Original manual page 1079
Read extracted page text

OCR can contain errors. Check the original page image for exact wording, warnings and specifications.

DME 7.8 DME 7.8 0 0-195P1600 216 CAN timeout PSM - open circuit Diagnosis conditions • Vehicle has PSM • Battery voltage greater than 10 V • Ignition on Possible fault cause ♦Wiring harness ♦PSM control module not connected ♦PSM control module faulty Note! ♦If all CAN bus faults are stored, there must be a short circuit in the CAN bus wiring. ♦If one CAN bus fault is stored, the cruise control system is out of order. ♦CAN bus faults may be caused by a control module reset. The fault is then indicated as "Not present". Affected terminals Terminal IV/36 and IV/37 Diagnosis/troubleshooting Work instruction Display OK If not OK 1 Check whether connector of PSM control module is plugged in. ⇒ Step 2 2 Check CAN bus from DME ♦Remove DME control module Repair wiring har- control module to PSM connector ness control module for conti- → End ♦Remove plug I from instrument nuity cluster ♦Remove PSM control module connector ♦Connect special tool 9637 to wiring harness (DME control module plug) P1600 0-195 page 1 Printed in Germany, 2000 p1600

This is a source reference. Confirm exact model applicability in the original material.