Porsche DME 7.8 — OBD II Diagnosis Manual / PAGE 1079
DME 7.8 DME 7.8 0 · 0-195P1600
Read extracted page text
OCR can contain errors. Check the original page image for exact wording, warnings and specifications.
DME 7.8 DME 7.8 0
0-195P1600
216 CAN timeout PSM - open circuit
Diagnosis conditions
• Vehicle has PSM
• Battery voltage greater than 10 V
• Ignition on
Possible fault cause
♦Wiring harness
♦PSM control module not connected
♦PSM control module faulty
Note!
♦If all CAN bus faults are stored, there must be a short circuit in
the CAN bus wiring.
♦If one CAN bus fault is stored, the cruise control system is out of
order.
♦CAN bus faults may be caused by a control module reset. The
fault is then indicated as "Not present".
Affected terminals
Terminal IV/36 and IV/37
Diagnosis/troubleshooting
Work instruction Display OK If not OK
1 Check whether connector of PSM control module is plugged in. ⇒ Step 2
2 Check CAN bus from DME ♦Remove DME control module Repair wiring har-
control module to PSM connector ness
control module for conti- → End ♦Remove plug I from instrument
nuity cluster
♦Remove PSM control module
connector
♦Connect special tool 9637 to
wiring harness (DME control
module plug)
P1600 0-195 page 1
Printed in Germany, 2000 p1600