fullymatted.
Back to search
Porsche DME 7.8 — OBD II Diagnosis Manual / PAGE 1083

DME 7.8 DME 7.8 0 · 0-196P1601

Add to repair workspace
Open repair workspace
Open full manual Original source
Original manual page 1083
Read extracted page text

OCR can contain errors. Check the original page image for exact wording, warnings and specifications.

DME 7.8 DME 7.8 0 0-196P1601 CAN timeout instrument cluster - signal implausible Diagnosis conditions • Battery positive voltage greater than 10 V • Ignition on Possible fault cause ♦Instrument cluster faulty Note! ♦If one CAN bus fault is stored, the cruise control system is out of order. ♦CAN bus faults may be caused by a control module reset. The fault is then indicated as "Not present". Affected terminals - Diagnosis/troubleshooting Replace instrument cluster. CAN timeout instrument cluster - open circuit Diagnosis conditions • Battery positive voltage greater than 10 V • Ignition on Possible fault cause ♦Wiring harness faulty ♦Plug on instrument cluster not connected ♦Instrument cluster faulty P1601 0-196 page 1 Printed in Germany – 8, 2002 p1601