Cooling Water Shutoff Valve - Above Limit
Diagnosis conditions
• Engine running
• Battery positive voltage greater than 7 V
Possible fault cause
♦Wiring harness
♦DME control module
Affected terminals
Terminal IV/40
Diagnosis/Troubleshooting
Work instruction Display OK If not OK
1 Check wiring from DME ♦Connect special tool 9637 to 0 V Repair wiring har-
control module to cool- wiring harness (DME control Step 2 ness
ant shutoff valve for short module plug) → End.
circuit to B+ ♦Remove connector of coolant
shutoff valve
♦Measure voltage between spe-
cial tool 9637 plug IV Pin 40 and
ground
♦Switch on the ignition.
2 Replace DME control module Step 3
3 Perform adaptation. ♦Switch on the ignition. → End.
♦Wait one minute.
♦Do not press the accelerator.
♦Switch off the ignition for at
least 10 seconds.
♦Read out the fault memory.
P1654 0-196.2 page 1