Porsche DME 7.8 — OBD II Diagnosis Manual / PAGE 1091
DME 7.8 DME 7.8 0 · 0-196.3P1655
Read extracted page text
OCR can contain errors. Check the original page image for exact wording, warnings and specifications.
DME 7.8 DME 7.8 0
0-196.3P1655
Cooling Water Shutoff Valve - Below Limit
Diagnosis conditions
• Engine running
• Battery positive voltage greater than 7 V
• Coolant temperature greater than 90 °C or ATF temperature >
85 °C
Possible fault cause
♦Wiring harness
♦DME control module
Affected terminals
Terminal IV/40
Diagnosis/Troubleshooting
Work instruction Display OK If not OK
1 Check wiring from DME ♦Connect special tool 9637 to ∞ Ω Repair wiring har-
control module to colant wiring harness (DME control Step 2 ness
shutoff valve for short to module plug) → End.
ground ♦Remove connector of coolant
shutoff valve
♦Measure resistance between
special tool 9637 plug IV Pin 40
and coolant shutoff valve plug
Pin 2
2 Replace DME control module Step 3
3 Perform adaptation. ♦Switch on the ignition. → End.
♦Wait one minute.
♦Do not press the accelerator.
♦Switch off the ignition for at
least 10 seconds.
♦Read out the fault memory.
P1655 0-196.3 page 1
Printed in Germany – 6, 2002 p1655