575 Coolant shutoff valve - below limit
Diagnosis conditions
• Engine running
• Battery voltage greater than 7 V
• Coolant temperature greater than 90 °C or ATF temperature >
85 °C
Possible fault cause
♦Wiring harness
♦DME control module
Affected terminals
Terminal IV/40
Diagnosis/troubleshooting
Work instruction Display OK If not OK
1 Check wiring from DME ♦Connect special tool 9637 to ∞ Ω Repair wiring har-
control module to colant wiring harness (DME control ⇒ Step 2 ness
shutoff valve for short to module plug) → End
ground ♦Remove connector of coolant
shutoff valve
♦Measure resistance between
special tool 9637 plug IV Pin 40
and coolant shutoff valve plug
Pin 2
2 Replace DME control module ⇒ Step 3
3 Perform adaptation ♦Switch on the ignition → End
♦Wait one minute
♦Do not press the accelerator
♦Switch off the ignition for at
least 10 seconds
♦Read out the fault memory
0-197 page 2 P1656
p1656 Printed in Germany, 2000